LogTag LogTag

The Logtag temperature logger is about the size of a credit card and offers:

 - 16,000 readings, 0.1°C resolution

 - programmable sampling rate

 - Push button or delayed start

 - Push button event recorder for staff

 - LED alarm indicator or temperature display


More Info button
FasTest Calibration Fittings FasTest Calibration Fittings

Calibrate Lots of Instruments - Fast!

FasTest’s “plug and play” modular connectors eliminate the traditional process of using tape sealant, wrenches and a bit of muscle to create leak tight connections. Comparisons of the FasTest way to traditional methods has shown at least a 5X efficiency improvement.

More Info button
Raytek Pi20 Fixed Thermal Camera Raytek Pi20 Fixed Thermal Camera

Raytek ThermoView™ cameras offer thermal imaging for moving or stationary targets in process control applications.

Combined with user-friendly software, these infrared cameras provide a complete solution for variety of industrial, as well as Lab and R&D applications.

More Info button
pR4116 Universal Transmitter pR4116 Universal Transmitter

The PReasy 4000 series is the latest example of reliable modules from PR electronics. The PReasy modules are designed to achieve the optimally efficient process, and we have focused on the following 3 characteristics in order to meet user needs:

• Universal – User-friendly – Reliable

More Info button
  • LogTag Thumbnail Image
  • FasTest Calibration Fittings Thumbnail Image
  • Raytek Pi20 Fixed Thermal Camera Thumbnail Image
  • pR4116 Universal Transmitter Thumbnail Image

Chlorine

ChemScan® Application Summary

Chlorination Control

Statement of the Problem:


Chlorination of water or wastewater is performed to destroy microbiological organisms and also to oxidize nitrogen or sulphur compounds, metals and organic substances. Chlorine will form hypochlorous acid (HOCl) and hypochlorite ion (OCl-) upon introduction to water. The relative percentage of these forms of free chlorine are pH dependent, as shown in Figure 1.


Apparatus:

Although the object of disinfection is the destruction of pathogenic organisms, the dosage of chlorine available for disinfection may be affected by the presence of other oxidizable matter that may exert a demand above the demand from pathogens.
Surface water treatment plants may experience a variable incoming concentration of natural organic matter (NOM) in the form of organic acids. These organic acids may only be partially removed during the treatment process, leaving a variable concentration in the water entering the primary disinfection process. Flow pacing alone may not assure that the necessary free chlorine residual has been established for the required contact period.


Control Strategy:

Analysis of free chlorine in the effluent from the primary chlorine contact basin is one strategy for control. This information is fed back to a controller, which adjusts the chlorine feed rate to maintain a target concentration in the effluent. It is important that the analytical technique be able to detect free chlorine (as opposed to combined chlorine). If there is a long contact time, feed back control may not provide a satisfactory response to variable demand conditions.
Where there is a variable demand from oxidizable material other than pathogens, another strategy is to monitor the incoming concentration of oxidizable material and use this information for feed forward or compound loop control of the chlorine feed rate.

In water, NOM can be detected directly by ChemScan. In wastewater, substantial demand can also be exerted from nitrite (NO2), which is another parameter ChemScan® can detect without reagents.

Hypochlorite ion has a strong absorbance signature in the ultraviolet wavelength range with a peak absorbance at 292 nm, while Hypochlorous acid has a weaker absorbance signature with a peak at 236 nm. As the pH of the sample is altered, the absorbance signature will rotate at 254 nm as the form of free chlorine is exchanged between HOCl and OCl- forms.

The ChemScan® Process Analyzer uses multiple wavelength light absorbance data to characterize the concentration of free chlorine in a sample of known or stable pH. If the pH is not known or is variable, sample pH can be adjusted to the 4-5 range, where HOCl is 100% of the form or to the 10+ range where OCl- is 100% of the form.Multiple wavelength absorbance can also be used to measure organics, nutrients or metals that may be present in the influent to chlorination process in order to calculate the effect that these constituents may have on the chlorination process.